Built for the trade

The calculator that draws your bends.

Drag the duct. Watch your marks move — in trade fractions, shrink included. Plus wire size, voltage drop, conduit fill and eight more answers in under ten seconds.

Join the beta $4.99 once at launch · no subscription
Bend guide — 30° offset Live demo
DUCT
drag the duct — up/down for rise, left/right for distance
Fully offlinebasements, slabs, no signal
Shows its mathformula + steps on every answer
No accountno ads, no tracking, nothing
$4.99 onceno subscription, ever
Calculators

Twelve answers. One search bar.

Type the problem the way you'd say it — "wire size 60 amps" — and you're there. Big controls that work with gloves on.

01

Bend guide

Offsets, 3-pt & 4-pt saddles, stubs, parallel runs, segment bends — with live diagrams.

02

Wire size

Termination limits, ambient correction, conductor count — names what governs.

03

Voltage drop

1φ & 3φ, K-factor or exact resistance, pass/fail against your target.

04

Conduit fill

EMT to LFMC, mixed sizes — finds the smallest size that fits.

05

Box fill

Full counting rules: yokes, clamps, grounds, fittings.

06

Motor circuit

FLC lookup, 125% conductors, breaker & fuse sizing.

07

Transformer

kVA and primary/secondary current, both phases.

08

Grounding

EGC by overcurrent device, GEC by service size.

09

Ohm's law

The power wheel — any two values solve the rest.

10

Ampacity

Corrected ampacity live as ambient and count change.

11

Dwelling load

Standard-method service sizing for residential.

12

Unit tools

AWG ↔ mm², kVA ↔ amps, temperature, length.

Why trust it

Checked against the book.

100%

Every constant verified

Every table value in the app was hand-checked against the published engineering data — then checked again by independent reviewers re-deriving the math from scratch.

95

Automated tests

Every calculator runs against hand-worked reference cases on every build. If a number drifts, the build fails before it ever reaches your phone.

1/16″

Trade fractions

Marks come out the way you read a tape — 31-5/8″, not 31.6087. Exact trig underneath, sixteenths on the screen.

Shows its work

No black boxes.

Every answer has a "How was this calculated?" sheet: the formula, the steps with your numbers plugged in, and the assumptions it made.

Check it against your code book once — that's the point. Apprentices learn from it. Journeymen verify with it. Inspectors respect it.

Wire size — the math
min size meets BOTH:
termination ampacity ≥ load × 1.25
base × √((Tc−Ta)/(Tc−30)) × adj ≥ load
Required at termination: 75 A → 4 AWG @ 75°C = 85 A
Corrected: 95 × 0.866 × 0.7 = 57.6 A — fails, size up
3 AWG: 110 × 0.866 × 0.7 = 66.7 A ≥ 60 A ✓
Straight answers

Fair questions.

I do this math in my head.

So does every journeyman — for the daily stuff. This is for the 4-point saddle you bend twice a year, the box fill an inspector questions, and the voltage drop on a 300-foot run you'd rather not redo.

How do I know the math is right?

Tap "How was this calculated?" on any answer and check it against your book — the formula and every step are right there. Every constant in the app was verified against published engineering data and is locked by automated tests.

Is this another subscription?

No. $4.99 once at launch. Every calculator, every future update, yours for good. No account, no ads, no tracking — your saved calculations never leave the phone.

Does it replace the code book?

No, and it doesn't try to. VoltWork computes from standard engineering formulas — it contains no code text. Results are an aid for qualified people; you verify against the edition your jurisdiction has adopted.

Now in beta

Get it first.

Free TestFlight beta for working electricians. Tell us what's wrong with it before anyone pays.

Join the beta